Sign in →

Test Code VBG Venous Blood Gas

Important Note

Ordered as VBG 

Alias

N/A

Collection Method

Venous Collection

Container

ABG Syringe 

Instructions/Special Handling

On ice

Preferred Specimen

ABG Syringe 

Acceptable Specimes

N/A

Units

N/A

Reference Ranges

pH Art - 7.35-7.45

pCO2 - 32-48mmHg

pO2 - 83- 108 mmHg

HCO3- 21-28 mmol/L

Base Excess -  -2.0- 3.0 (mmol/L)

O2Sat - 60-85%

Critical Values

pH Art - <7.20 - >7.60

pCO2 - <20 - >70 mmHg

pO2 - <40 - n/a mmHg

HCO3 <10- >40 mmol/L

Base Excess - none (mmol/L)

O2Sat - none (%) 

Reasons for Rejection

Hemolysis N/A
Icterus N/A
Lipemia N/A
Other QNS, Contaminated, Improperly labeled, Improper specimen type, Clotted

 

Specimen Stability

Ambient (15-25°C) 30 Minutes
Refrigerated (2-8°C) 1 hour (on ice)
Frozen (-20°C) N/A

 

Performing Site

Boone Health Laboratory

Performance Information

Days/Times Performed Daily 24/7
Expected Turn around Time Same day
Methodology/Method Description GEMs 

CPT Code(s)

82805

Panel Components

N/A